{"product_id":"60054-electrosurgical-unit-diathermy-machine-400-dx","title":"Electrosurgical Unit (Diathermy Machine) 400 DX+","description":"\u003cp\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003e\u003cb\u003ePRODUCT DETAILS :\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"margin-bottom: 0px; padding: 0px; border: 0px;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003e\r\n\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eThe 400 DX+ is a 400-watt high power, operating room generator\/electrosurgical unit. The unit consists tissue impedance monitoring system, self-adjustment of power output to reduce the continuous power setting for different tissue needs, to provide user consistent performance with all digital displays of power and modes. \r\n  The system delivers 9 monopolar and bipolar RF energy modalities to provide a high level of surgical precision. Engineered with the safety of the patient in mind\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cp\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003e\u003cb\u003eSPECIAL FEATURES :\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"margin: 0px; padding: 5px 0px 0px; border: 0px; line-height: 28px; list-style: circle;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eA tissue sensing technology used for all applications to deliver user consistent performance.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin: 0px; padding: 5px 0px 0px; border: 0px; line-height: 28px; list-style: circle;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eReduce the frequent adjustment of power setting as the tissue changes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin: 0px; padding: 5px 0px 0px; border: 0px; line-height: 28px; list-style: circle;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eReduce the risk of collateral tissue damage due to sparkles and charring free power.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin: 0px; padding: 5px 0px 0px; border: 0px; line-height: 28px; list-style: circle;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eMinimize the patient recovery time by performing precise and clean cutting and coagulation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin: 0px; padding: 5px 0px 0px; border: 0px; line-height: 28px; list-style: circle;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eMinimum RF distortion in other O.T. Equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin: 0px; padding: 5px 0px 0px; border: 0px; line-height: 28px; list-style: circle;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003ePatient plate fault monitoring system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin: 0px; padding: 5px 0px 0px; border: 0px; line-height: 28px; list-style: circle;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eThe auto-monitoring facility displays different error codes if any error occurs during use.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin: 0px; padding: 5px 0px 0px; border: 0px; line-height: 28px; list-style: circle;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eTwo independent power activation of monopolar output, hand switch operation, and footswitch operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin: 0px; padding: 5px 0px 0px; border: 0px; line-height: 28px; list-style: circle;\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eSeparate bipolar generator with foot switch operation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003ctable class=\"table table-bordered\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003eMono Cut\u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003eWatt (W)\u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003eR (Ohm)\u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003eC Factor\u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePure\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e400 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e500 Ohm\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.5\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlend\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e350 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e500 Ohm\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eVariable\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndo Cut\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e250 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e500 Ohm\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eVariable\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003eMono Coag\u003c\/span\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoft\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e200 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e500 Ohm\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.5\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForce\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e175 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e500 Ohm\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eVariable\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDessicate\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e150 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e500 Ohm\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eVariable\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003eB\u003c\/span\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003eipolar\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBi-CuT\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e150 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100 Ohm\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicro\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e300 Ohm\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTD\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e150 W\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100 Ohm\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.5\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003e\u003cb\u003eTECHNICAL DATA\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eInput: 220\/240 VAC \/ 50Hz\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003ePower Consumption: 750 VA Max.\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eProtection Class: 1\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eMDD: IIB\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eInput Fuse: 6 AMP\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eOutput Control: Digital Display\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eNominal Frequency: MDD360Khz\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eMax. Output Power: 400 W\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eBasic Construction: IEC-60501-1, IEC-60601-1-2\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eDimension: 390*130*340mm\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"margin: 0px; padding: 0px; border: 0px;\"\u003eAmbient Temperature: 30-40 Deg. C\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"border-style: initial; border-color: initial; border-image: initial;\"\u003eWeight: 6.5 Kg.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"IndoSurgicals","offers":[{"title":"Default Title","offer_id":48766314709209,"sku":"60054","price":58650.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/3004\/0793\/files\/60054-electrosurgical-unit-diathermy-machine-400-dx.jpg?v=1780081235","url":"https:\/\/meddeal.in\/products\/60054-electrosurgical-unit-diathermy-machine-400-dx","provider":"MedDeal","version":"1.0","type":"link"}